<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-12 15-31-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 45 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.7 kHz 89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 58 kHz 11250 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,1 dBr 2,22 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Anne L'Esperance (sopraano), Jane Archibald (sopraano), Michele "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 58 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/12 15.30.28 Total samples: 11250 Equivalent time: 0:09:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 4,3 dBr MIN: 1,1 dBr AVE: 2,22 dBr % above 12,2 dBr: 0,0 Last value: 1,9 dBr (2025/12/12 15.30.27) 15.16 15.18 15.20 15.22 15.24 15.26 15.28 15.30 0 2 4 Pm [dBr]